Table 2-2.  Preventive Maintenance Checks and Services (M1078 and M1081) - TM-9-2320-365-10_198
PREVENTIVE MAINTENANCE CHECKS AND SERVICES TABLE (M1081 AIR DROP SPECIFIC)

/.5tonv1-2/TM-9-2320-365-10 Palletized Load System Model M1074/M1075 NSN 2320-01-304-2277 2320-01-304-2278 Manual
Page Navigation
  157    158    159    160    161  162  163    164    165    166    167  
TM 9-2320-365-10 Table 2-2.  Preventive Maintenance Checks and Services (M1078 and M1081) (Cont) Location Item No. Interval Item to Check/ Service Crewmember Procedure Not Fully Mission Capable If: 10 Monthly LMHC (if equipped) (Cont) c.   Six randomly distributed broken wires in any 6 in. (150 mm) section of cable or three broken wires in on bundle (breaks 3,4,5) in a 6 in. (150 mm) section. d.   Kinking, crushing, or any other damage resulting in distortion of the cable structure. e.   Check security of electrical connectors on overload shutdown box. f. Inspect electrical cables for cracking, fraying, and chaffing. f. Wiring is frayed, cracked, or excessively worn. Change 1 2-109