  206    207    208    209    210  211  212    213    214    215    216  
TM 9-2320-365-10 f.   Shut Down Engine. (1)   Stop vehicle (para 2-21d). (2)   Press N (Neutral) button (1) on WTEC II TEPSS (2) or WTEC III TPSS (2). (3)   Pull out SYSTEM PARK control (3). CAUTION •  Engine temperature must be maintained at a minimum of 165 F (74 C) for final 15 minutes prior to engine shutdown. Failure to comply may result in damage to engine. •  When  outside  temperatures  are  below  32  F  (0  C)  do  not  continuously operate engine above 1,250 to 1,450 rpm or HAND THROTTLE lever above L.   Failure to comply may result in damage to equipment. NOTE •  Steps   (4)   through   (6)   are   only   necessary   to   meet   165   F   (74   C) requirements. •  Perform step (4) if it is necessary to increase WATER TEMP to 165 F (74 C) and it can be accomplished using accelerator pedal or HAND THROTTLE lever, within approximately 20 minutes. •  In the event of a tachometer failure a HAND THROTTLE lever positioned to L is approximately 1,250 to 1,450 rpm. (4)   Set engine speed to 1,250 to 1,450 rpm or place HAND THROTTLE lever (4) to L until WATER TEMP gage (5) reaches and maintains 165  F (74  C) for 15 minutes. 2-157