Change 1 2-203TM 9-2320-365-34-1CONTINUITY TESTCAUTIONUse care when disconnecting transmission internal wiring harness connectors. Failure tocomply may result in damage to equipment.(10) Connect negative (-) probe of multimeter to ground and note reading on multimeter.(11) If continuity is present, transmission internal wiring harness is shorted; replace transmission wiring harness (para 7-13).(1) Remove control valve module (para 7-10).(2) Remove four screws and cover from control valve module.(3) Disconnect internal wiring harnessconnector A from A solenoid connector.(4) Set multimeter to ohms.(5) Connect positive (+) probe of multimeter to internal wiring harness 24-pin connectorpin A1.(6) Connect negative (-) probe of multimeter tointernal wiring harness connector A pin A and note reading on multimeter.(7) If continuity is not present, replace transmission internal wiring harness (para 7-13).(8) Connect positive (+) probe of multimeter to internal wiring harness 24-pin connectorpin A1.(9) Connect negative (-) probe of multimeter to all other pins in internal wiring harness24-pin connector, except A2, D1, and H1,and note reading on multimeter.