TM 9-2320-365-34-2
7-10. CONTROL VALVE MODULE REPLACEMENT (CONT)
b. Installation.
(1) Install gasket (1) on control valve module (2).
WARNING
Control valve module weighs approximately
65 lbs (30 kgs). Position a floor jack under
control module prior to installation. Failure
to comply may result in injury to personnel
or damage to equipment.
(2) Position control valve module (2) on main housing
module (3) with 18 screws (4).
NOTE
Perform step (3) on transmissions serial
number 6510032369 and higher.
(3) Position transmission adapter harness (5) and control
valve module (2) on main housing module (3) with 20
screws (4).
(3.1) Tighten screws (4) to 38-45 lb-ft (51-61 N·m).
(4) Connect oil hose (11) to 45-degree fitting (12) on
control valve module (2).
7-72
Change 1