TM 9-2320-365-34-2
NOTE
Perform step (4) on M1078/M1079.
(4) Remove two self-locking nuts (11), bolts (12), and
brackets (13) from frame rail (4). Discard self-locking
nuts.
CAUTION
When removing bolts, continuous removal of
collars is mandatory. Failure to comply will
result in seizing of collar to bolt.
NOTE
Steps (5) through (13) require the aid of an
assistant.
(5) Remove two collars (14), bolts (15), and brackets (16)
from frame rail (4). Discard collar and bolt.
NOTE
Perform step (6) on M1078/M1079.
(6) Remove six collars (17), bolts (18), and two frame plates
(19) from frame rail (4). Discard collars and bolts.
Change 1
13-55