TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e6.
FUEL GAGE DOES NOT OPERATE OR IS INACCURATE.
Step 1. Fill fuel tank.
If FUEL gage shows less than full, notify Unit Maintenance.
Step 2. Check circuit breaker (CB77) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(c)
Position master power switch to on (para 2-21a or b).
(d)
Check circuit breaker to see if it tripped again. If circuit breaker is tripped again, notify Unit
Maintenance.
(e)
Position master power switch to off (para 2-21f).
(f)
Install PDP cover (para 3-13b).
(g)
If FUEL gage still does not operate or is inaccurate, notify Unit Maintenance.
e7.
WATER TEMP GAGE DOES NOT OPERATE OR IS INACCURATE.
Check circuit breaker (CB77) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker in electrical panel to see if it tripped. If circuit breaker tripped again,
notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If WATER TEMP gage still does not operate or is inaccurate, notify Unit Maintenance.
e8.
REAR BRAKE AIR PRESSURE GAGE DOES NOT OPERATE OR IS INACCURATE.
Step 1. Check to see if there is air in air tanks.
(a)
Start engine (para 2-21a or b).
(b)
Allow vehicle to idle for approximately two minutes.
(c)
Shut down engine (para 2-21f).
Change 1
3-29