CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin A.
(3) Connect negative (-) probe of multimeter to
adapter cable 24-pin connector pin A2 and
note reading on multimeter.
(4) If continuity is not present, replace
transmission adapter cable assembly
(para 6-8).
(5) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin A.
(6) Connect negative (-) probe of multimeter to
all other pins in adapter cable 31-pin
connector and note reading on multimeter.
(7) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(8) If continuity is present, transmission adapter
cable assembly is shorted; replace
transmission adapter cable assembly
(para 6-8).
(9) Connect adapter cable 31-pin connector to
external wiring harness 31-pin connector.
Change 1 2-293
TM 9-2320-365-34-1