TM 9-2320-365-34-1Change 1 2-343RESISTANCE TESTCAUTIONNOTEUse care when testing electrical connectors.Do not damage connector pins or socketswith multimeter probes. Failure to complymay result in damage to equipment.Inspect connector pins/sockets for damage,corrosion, and serviceability. Check thatconnector pins are not pushed back andare capable of making good contact.(1) Set multimeter to ohms.(2) Connect positive (+) probe of multimeter toE solenoid connector pin A.(3) Connect negative (-) probe of multimeter toE solenoid connector pin B and notereading on multimeter.(4) If resistance is less than 2.5 ohms orgreater than 5.0 ohms, replaceE solenoid (para 7-7).(5) If resistance is between 2.5-5.0 ohms,replace WTEC II TEPSS (TM 9-2320-365-20-3).(6) Connect internal wiring harness connector Eto E solenoid connector.(7) Install cover on control valve module withfour screws.(8) Install control valve module (para 7-10).(9) Connect batteries (TM 9-2320-365-20-3).