Change 1 2-635
TM 9-2320-365-34-1
CONTINUITY TEST
CAUTION
Use care when disconnecting wiring harness
connectors. Failure to comply may result in
damage to equipment.
(1) Loosen screw in adapter cable 24-pin
connector.
(2) Disconnect adapter cable 24-pin connector
from internal wiring harness 24-pin
connector.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin N.
(5) Connect negative (-) probe of multimeter
to adapter cable 24-pin connector pin G2
and note reading on multimeter.
(6) If continuity is not present, replace
transmission adapter cable assembly
(para 6-8).
(7) Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin N.
(8) Connect negative (-) probe of multimeter
to all other pins in adapter cable 31-pin
connector and note reading on multimeter.
(9) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(10) If continuity is present, transmission
adapter cable assembly is shorted; replace
transmission adapter cable assembly
(para 6-8).