TM 9-2320-365-34-1
Change 1 2-825
CONTINUITY TEST
(1) Remove control valve module (para 7-10).
(2) Remove four screws and cover from
control valve module.
(3) Disconnect internal wiring harness
connector G from G solenoid.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to internal wiring harness 24-pin connector
pin F1.
(6) Connect negative (-) probe of multimeter
to internal wiring harness connector G
pin A and note reading on multimeter.
(7) If continuity is not present, replace
transmission internal wiring harness
(para 7-13).
(8) Connect positive (+) probe of multimeter
to internal wiring harness 24-pin connector
pin F1.
(9) Connect negative (-) probe of multimeter
to all other pins in internal wiring harness
24-pin connector and note reading on
multimeter.
(10) Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(11) If continuity is present, transmission
internal wiring harness is shorted; replace
transmission internal wiring harness
(para 7-13).