Change 1 2-241
TM 9-2320-365-34-1
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to pin A of B solenoid connector.
(3) Connect negative (-) probe of multimeter
to pin B of B solenoid connector and note
reading on multimeter.
(4) If resistance is less than 2.5 or greater
than 5.0 ohms, replace B solenoid
(para 7-8).
(5) If resistance is between 2.5-5.0 ohms,
replace WTEC II TEPSS (TM 9-2320-365-
20-3).
(6) Connect internal wiring harness connector
B to B solenoid connector.
(7) Install cover on control valve module with
four screws.
(8) Install control valve module (para 7-10).
(9) Connect batteries (TM 9-2320-365-20-3).