TM 9-2320-365-34-26-6. STARTING MOTOR REPAIR (P/N M0017703ME) (CONT)(44) Remove field coil screw (15) from field ring (22).(45) Remove preformed packing (67) and insulation bushing(68) from field ring (22). Discard preformed packing andinsulation bushing.b. Cleaning/Inspection.WARNING• Dry cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; useonly in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I drycleaning solvent is 100 ° F (38 ° C) and for Type II is 130 ° F (50 ° C). Failure to comply mayresult in serious injury or death to personnel.• If personnel become dizzy while using dry cleaning solvent, immediately get fresh air and medicalhelp. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,immediately flush eyes with water and get immediate medical attention. Failure to comply mayresult in injury to personnel.•Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only witheffective chip guarding and personal protective equipment (goggles/shield, gloves, etc). Failureto comply may result in injury to personnel.6-36.4 Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business