TM 9-2320-365-34-2
(3) Remove fitting (3) and 90 degree fitting (4) from
hydraulic rotary pump (8).
(4) Remove preformed packings (9 and 10) from fitting (3)
and 90 degree fitting (4).
b. Installation.
(1) Install preformed packings (1 and 2) on fittings (3) and
90 degree fitting (4).
(2) Install fitting (3) and 90 degree fitting (4) in hydraulic
rotary pump (5).
NOTE
Step (3) requires the aid of an assistant.
(3) Position hydraulic rotary pump (5) on PTO (6) with two
washers (7) and screws (8).
(4) Tighten two screws (8) to 58-78 lb-ft (79-105 N m).
(5) Connect hydraulic hoses (9 and 10) to fitting (3) and 90
degree fitting (4).