TM 9-2320-365-34-218-3. 200 AMP ALTERNATOR REPAIR (CONT)WARNINGAdhesives, solvents, and sealing compoundscan burn easily, can give off harmful vapors,and are harmful to skin and clothing. Keepaway from open fire and use in a well-ventilated area. If adhesive, solvent, orsealing compound gets on skin or clothing,wash immediately with soap and water.Failure to comply may result in injury topersonnel.(25) Apply sealing compound to head of screw (26), terminallug (30), jumpers (28 and 29), five screws (27), terminallugs (32), and jumpers (33).CAUTIONUse care when installing diode plate onstator. Failure to comply may result indamage to equipment.(26) Position diode plate (35) on front housing (15) with ninelockwashers (36) and screws (37).(27) Tighten nine screws (37) to 30 lb-in. (3 N·m).18-22 Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business