TM 9-2320-365-34-2(28) Position six terminal lugs (38) on diode plate (35) withsix lockwashers (39) and screws (40).(29) Tighten six screws (40) to 30 lb-in. (3 N·m).WARNINGAdhesives, solvents, and sealing compoundscan burn easily, can give off harmful vapors,and are harmful to skin and clothing. Keepaway from open fire and use in a well-ventilated area. If adhesive, solvent, orsealing compound gets on skin or clothing,wash immediately with soap and water.Failure to comply may result in injury topersonnel.(30) Apply sealing compound to six screws (40) and terminallugs (38).(31) Position washer (41), lockwasher (42), and screw (43) indiode plate (35).(32) Position terminal lugs (44, 45 and 46) on terminal block(47).(33) Tighten three screws (48) on terminal block (47) to 30 lb-in. (3 N·m).(34) Apply sealing compound to three screws (48) andterminal lugs (44, 45, and 46).Change 1 18-23