TM 9-2320-365-34-2b. Installation.(1) Install seal (1) in housing (2).(2) Install gasket (3) on channel plate (4).(3) Install strainer (5) on channel plate (4).NOTEPerform steps (4) and (5) on serial number6510032369 and higher.(4) Position housing (2) on channel plate (4) with threebolts (6).(5) Tighten three bolts (6) to 108-120 lb-in. (12-14 N·m).NOTEPerform steps (6) and (7) on serial numbersprior to 6510032369.(6) Position housing (2) on channel plate (4) with fourbolts (6).(7) Tighten four bolts (6) to 108-120 lb-in. (12-14 N·m).c. Follow-On Maintenance.Install control valve module (para 7-10).End of Task.7-93