TM 9-2320-365-34-2CAUTIONUse care when disconnecting harnessconnectors. Failure to comply may result indamage to equipment.NOTE• Tag wires and connection points prior todisconnecting.• Perform steps (2) through (5) on serial numbersprior to 6510032369.(2) Disconnect harness (4) from nine solenoids (5).(3) Disconnect harness (4) from pressure switch (6).(4) Disconnect harness (4) from turbine speed sensor (7).(5) Remove two bolts (8) and harness (4) from channelplate (9).NOTEPerform steps (6) through (9) on serialnumber 6510032369 and higher.(6) Disconnect harness (4) from nine solenoids (5).(7) Disconnect harness (4) from pressure switch (6).(8) Disconnect harness (4) from turbine speed sensor (7).(9) Remove two bolts (8) and harness (4) from channelplate (9).Change 1 7-89