TM 9-2320-365-34-2
CAUTION
Use care when disconnecting harness
connectors. Failure to comply may result in
damage to equipment.
NOTE
Tag wires and connection points prior to
disconnecting.
Perform steps (2) through (5) on serial numbers
prior to 6510032369.
(2) Disconnect harness (4) from nine solenoids (5).
(3) Disconnect harness (4) from pressure switch (6).
(4) Disconnect harness (4) from turbine speed sensor (7).
(5) Remove two bolts (8) and harness (4) from channel
plate (9).
NOTE
Perform steps (6) through (9) on serial
number 6510032369 and higher.
(6) Disconnect harness (4) from nine solenoids (5).
(7) Disconnect harness (4) from pressure switch (6).
(8) Disconnect harness (4) from turbine speed sensor (7).
(9) Remove two bolts (8) and harness (4) from channel
plate (9).
Change 1
7-89