TM 9-2320-365-34-2
11-2. AIR COMPRESSOR REPLACEMENT (CONT)
(15) Connect ether sensor switch connector (21) to electrical
connector P-42 (22).
(16) Connect connector clamp (23) on either sensor switch
connector (21).
(17) Install clamp (24) on bracket (25) with screw (26),
washer (27), and self-locking nut (28).
WARNING
Adhesives, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep
away from open fire and use in a well-
ventilated area.
If adhesive, solvent, or
sealing compound gets on skin or clothing,
wash immediately with soap and water.
Failure to comply may result in injury to
personnel.
(17.1) Apply sealant to threads of bolt (31).
(18) Position support bracket (29) on air compressor (1) with
washer (30) and bolt (31).
(19) Position two washers (32) and bolts (33) in bracket (29).
(20) Tighten bolt (31) to 28-38 lb-ft (38-52 N·m).
(21) Tighten two bolts (33) to 25-31 lb-ft (35-43 N·m).
(21.1) Tighten bolt (34) to 18-22 lb-ft (24-30 N·m).
11-8