TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e103.
M1079 110 VAC OUTLET J234 DOES NOT OPERATE (CONT).
(c)
Check to see if 110 vac outlet J234 operates.
(d)
If 110 vac outlet J234 does not operate, or circuit breaker trips again, notify Unit
Maintenance.
e104.
M1079 110 VAC OUTLET J235 DOES NOT OPERATE.
Check circuit breaker (CB9) in 110/208 VAC POWER DISTRIBUTION PANEL to see if it is tripped.
(a)
Open 110/208 VAC POWER DISTRIBUTION PANEL cover (para 2-32).
(b)
If circuit breaker is tripped, position to ON to reset.
(c)
Check to see if 110 vac outlet J235 operates.
(d)
If 110 vac outlet J235 does not operate, or circuit breaker trips again, notify Unit
Maintenance.
e105.
M1079 110 VAC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE.
Check circuit breaker (CB5) in 110/208 VAC POWER DISTRIBUTION PANEL to see if it is tripped.
(a)
Open 110/208 VAC POWER DISTRIBUTION PANEL cover (para 2-32).
(b)
If circuit breaker is tripped, position to ON to reset.
(c)
Check to see if 110 vac outlet J232 operates.
(d)
If 110 vac outlet J232 does not operate, or circuit breaker trips again, notify Unit
Maintenance.
e106.
M1079 110 VAC OUTLET J232 AND J233 DO NOT OPERATE IN BLACKOUT
OVERRIDE MODE.
Check circuit breaker (CB5) in 110/208 VAC POWER DISTRIBUTION PANEL to see if it is tripped.
(a)
Open 110/208 VAC POWER DISTRIBUTION PANEL cover (para 2-32).
(b)
If circuit breaker is tripped, position to ON to reset.
(c)
Check to see if 110 vac outlets J232 and J233 operate.
(d)
If 110 vac outlets J232 and J233 do not operate, or circuit breaker trips again, notify Unit
Maintenance.
e107.
M1079 110 VAC OUTLET J231 DOES NOT OPERATE.
Check circuit breaker (CB7) in 110/208 VAC POWER DISTRIBUTION PANEL to see if it is tripped.
(a)
Open 110/208 VAC POWER DISTRIBUTION PANEL cover (para 2-32).
3-66
Change 1