TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e92.
RADIO DOES NOT OPERATE.
Check circuit breaker (CB20) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position radio to off.
(c)
Position master power switch to off (para 2-21f).
(d)
If circuit breaker is tripped, push in to reset.
(e)
Position master power switch to on (para 2-21a or b).
(f)
Position radio to on.
(g)
If circuit breaker is tripped or trips again, notify Unit Maintenance.
(h)
Position master power switch to off (para 2-21f).
(i)
Install PDP cover (para 3-13b).
(j)
If radio still does not operate, notify Unit Maintenance.
e93.
START INHIBIT PUSHBUTTON DOES NOT OPERATE.
Check circuit breaker (CB79) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Attempt to start engine (2-21a or b).
(e)
Position master power switch to on (para 2-21a or b).
(f)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
e94.
AIR DRYER DOES NOT OPERATE.
Notify Unit Maintenance.
e95.
BATTERY TESTER DOES NOT OPERATE.
Notify Unit Maintenance.
e96.
M1079 FAN DOES NOT OPERATE.
Check circuit breaker (CB8) in 110/208 VAC POWER DISTRIBUTION PANEL to see if it is tripped.
(a)
Open 110/208 VAC POWER DISTRIBUTION PANEL cover (para 2-32).
(b)
If circuit breaker is tripped, position to ON to reset.
3-64
Change 1