TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e85.
POWER TAKE-OFF (PTO) DOES NOT OPERATE.
Check circuit breaker (CB49) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If PTO still does not operate, notify Unit Maintenance.
e86.
ELECTRICAL SYSTEM DOES NOT MAINTAIN A CHARGE.
Step 1. Check to see if battery cables and terminal posts are OK.
(a)
Remove battery box cover (para 3-8a).
(b)
Check battery cables for apparent damage and corrosion.
If corrosion is present or battery cables are damaged, notify Unit Maintenance.
(c)
Check terminal posts for corrosion.
If corrosion is present, notify Unit Maintenance.
Step 2. Check fluid level in battery cells (para 3-8b).
If fluid level is low, notify Unit Maintenance.
(a)
Install battery box cover (para 3-8c).
Step 3. Check to see if engine oil pressure indicator light illuminates.
(a)
Position master power switch to on (para 2-21a or b).
If engine oil pressure indicator light does not illuminate, notify Unit Maintenance.
(b)
Position master power switch to off (para 2-21f).
Step 4. Check to see if OIL PRESS. gage operates.
(a)
Start engine (para 2-21a or b).
If OIL PRESS. gage does not operate, notify Unit Maintenance.
(b)
Shut down engine (para 2-21f).
Change 1
3-61