TM 9-2320-365-34-2NOTEStep (4) requires the aid of an assistant.(4) Remove clutch piston (4), outer sealring (5), and innersealring (6) from adapter housing (2). Discard sealrings.(5) Remove plug (7) and strainer (8) from adapter housing(2).(6) Remove preformed packing (9) from plug (7). Discardpreformed packing.b. Cleaning/Inspection.WARNINGDry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathevapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint forType I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to complymay result in injury or death to personnel.If personnel become dizzy while using cleaning solvent, immediately get fresh air and medicalhelp. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaningsolvent contacts eyes, immediately flush eyes with water and get immediate medical attention.Failure to comply may result in injury to personnel.(1) Clean all metal parts with dry cleaning solvent.NOTEReplace any part that fails visual inspection.Crocus cloth may be used to remove nicks,burrs, or scratches.(2) Inspect adapter housing (1) for cracks, nicks, scoring,and burring.21-37