TM 9-2320-365-34-221-7. P3 PLANETARY CARRIER MODULE REPAIR (CONT)WARNINGUse care when installing retaining rings.Retaining rings are under tension and canact as projectiles when released. Failureto comply may result in injury topersonnel.(4) Install indexing ring (7) and retaining ring (8) in planetarycarrier (2).d. Follow-On Maintenance.Assemble transmission (para 21-2).End of Task.21-42