TM 9-2320-365-34-26-2. 100 AMP ALTERNATOR REPAIR (CONT)WARNINGAdhesive Sealant MIL-S-46163candamage your eyes. Wear safety goggleswhen using; avoid contact with eyes. Ifsealant contacts eyes, flush with waterand get immediate medical attention.Failure to comply may result in injury topersonnel.(13) Apply sealing compound to threads of three screws (14).(14) Position rotor (15) on shaft (3) with three washers (16),lockwashers (17), and screws (14).(15) Tighten three screws (14) to 45 lb-in. (5 N•m).(16) Install bearing (18) in end housing (19).(17) Position end housing (19) on stator (12) withmatchmarks aligned.(18) Position nine self-locking nuts (20) on stator (12).(19) Tighten nine self-locking nuts (20) to 45 lb-in. (5 N•m).(20) Install six washers (21) and coil leads (22) on fronthousing (7) with six nuts (23).6-8