TM 9-2320-365-34-26-2. 100 AMP ALTERNATOR REPAIR (CONT)CAUTIONNuts securing field leads and coil leads arenot interchangeable. Tag field lead nutsduring removal. Failure to comply may resultin damage to equipment.NOTETag coil leads and connection points prior todisconnecting.(9) Remove six nuts (25), coil leads (26), and washers(27) from front housing (9).(10) Match mark end housing (21) to stator (17).(11) Remove nine self-locking nuts (28) and end housing(21) from stator (17). Discard self-locking nuts.(12) Remove bearing (29) from shaft (3).(13) Remove three screws (30), lockwashers (31), andwashers (32) from rotor (33). Discard lockwashers.(14) Install three jacking screws in small threaded holeson rotor (33).(15) Remove rotor (33) from shaft (3) by alternatelyturning three jacking screws two full turns.(16) Remove three jacking screws from rotor (33).6-4