TM 9-2320-365-34-2
6-2. 100 AMP ALTERNATOR REPAIR (CONT)
(26) Remove three screws (40), lockwashers (41), and
washers (42) from rotor (43). Discard lockwashers.
(27) Install three jacking screws in small threaded holes
in rotor (43).
(28) Remove rotor (43) from shaft (3) by alternately
turning jacking screws two full turns.
(29) Remove three jacking screws from rotor (43).
b. Assembly.
WARNING
Adhesive
Sealant
MIL-S-46163
can
damage your eyes. Wear safety goggles
when using; avoid contact with eyes. If
sealant contacts eyes, flush with water
and get immediate medical attention.
Failure to comply may result in injury to
personnel.
(1) Apply sealing compound to threads of three screws (1).
(2) Position rotor (2) on shaft (3) with three washers (4),
lockwashers (5) and screws (1).
(3) Tighten three screws (1) to 45 lb-in. (5 Nm).
6-6