TM 9-2320-365-34-2
(5) Disconnect connector (13) from voltage regulator (14).
(6) Remove two screws (15), lockwashers (16), and voltage
regulator (14) from stator (17). Discard lockwashers.
(7) Remove four screws (18), washers (19), and fan
guard (20) from end housing (21).
CAUTION
Nuts securing field leads and coil leads are
not interchangeable.
Tag field lead nuts
during removal. Failure to comply may result
in damage to equipment.
NOTE
Tag field leads and connection points prior to
disconnecting.
(8) Remove two nuts (22), field leads (23), and
washers (24) from front housing (9).
6-3