TM 9-2320-365-34-2
(5) Position bracket (6) on valve panel (7) with six washers
(8), three screws (9), and self-locking nuts (10).
(6) Tighten three self-locking nuts (10) to 14-18 lb-ft (20-24
N·m).
(7) Position three bolts (11) in bracket (12) with three self-
locking nuts (13).
(8) Tighten three self-locking nuts (13) to 210-225 lb-ft (285-
305 N·m).
NOTE
Install plastic cable ties as required.
(9) Install 90-degree fitting (14) in frame rail (15) with nut
(16).
(10) Connect hose (17) to 90-degree fitting (14).
13-21