TM 9-2320-365-34-218-3. 200 AMP ALTERNATOR REPAIR (CONT)(35) Remove six self-locking nuts (74) and washers (75) fromrotor (76). Discard self-locking nuts.(36) Match mark rotor (76) to shaft (3).(37) Install three jacking screws in small threaded holes inrotor (76).(38) Remove rotor (76) from shaft (3) by alternately turningthree jacking screws two full turns.(39) Remove three jacking screws from rotor (76).(40) Remove nut (77), lockwasher (78), washer (79), and fuse(80) from 24 vdc post (33). Discard lockwasher.(41) Remove nut (81), lockwasher (82), and washer (83) from12 vdc post (39). Discard lockwasher.b. Assembly.(1) Position washer (1) and lockwasher (2) on 12 vdc post(3) with nut (4).(2) Position fuse (5), washer (6), and lockwasher (7) on 24vdc post (8) with nut (9).18-18 Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business