TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e77.
CHEMICAL ALARM DOES NOT OPERATE (CONT).
(f)
Install PDP cover (para 3-13b).
(g)
If chemical alarm still does not operate, notify Unit Maintenance.
e78.
CHEMICAL DETECTOR DOES NOT OPERATE.
Check circuit breaker (CB30) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If chemical detector still does not operate, notify Unit Maintenance.
e79.
CENTRAL TIRE INFLATION SYSTEM (CTIS) DOES NOT OPERATE.
Check circuit breaker (CB40) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If CTIS still does not operate, notify Unit Maintenance.
e80.
CENTRAL TIRE INFLATION SYSTEM (CTIS) DOES NOT INFLATE TIRES.
Step 1. Check operation of CTIS to deflate tires (para 2-23).
If CTIS does not deflate tires, notify Unit Maintenance.
3-58
Change 1