TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e80.
CENTRAL TIRE INFLATION SYSTEM (CTIS) DOES NOT INFLATE TIRES (CONT).
Step 2. Check circuit breaker (CB40) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If CTIS still does not inflate tires, notify Unit Maintenance.
e81.
CENTRAL TIRE INFLATION SYSTEM (CTIS) DOES NOT DEFLATE TIRES.
Step 1. Check operation of CTIS to inflate tires (para 2-23).
If CTIS does not inflate tires, notify Unit Maintenance.
Step 2. Check circuit breaker (CB40) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Install PDP cover (para 3-13b).
(g)
Position master power switch to off (para 2-21f).
(h)
If CTIS still does not deflate tires, notify Unit Maintenance.
e82.
11K SELF-RECOVERY WINCH (SRW) DOES NOT REEL IN OR PAY OUT.
Check circuit breaker (CB49) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
Change 1