TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e70.
PERSONNEL HEATER FAN DOES NOT OPERATE.
Check circuit breaker (CB23) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker in PDP to see if it is tripped. If circuit breaker is tripped, notify Unit
Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If personnel heater fan still does not operate, notify Unit Maintenance.
e71.
WINDSHIELD WASHER DOES NOT OPERATE.
Check circuit breaker (CB37) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If windshield washer still does not operate, notify Unit Maintenance.
e72.
WINDSHIELD WIPER DOES NOT OPERATE ON LOW SPEED.
Check circuit breaker (CB37) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
Change 1
3-55