TM 9-2320-365-10
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e82.
11K SELF-RECOVERY WINCH (SRW) DOES NOT REEL IN OR PAY OUT (CONT).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If 11K SRW still does not reel in or pay out, notify Unit Maintenance.
e83.
11K SELF-RECOVERY WINCH (SRW) DOES NOT REEL IN.
Check circuit breaker (CB49) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If 11K SRW still does not reel in, notify Unit Maintenance.
e84.
11K SELF-RECOVERY WINCH (SRW) DOES NOT PAY OUT.
Check circuit breaker (CB49) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-13a).
(b)
Position master power switch to off (para 2-21f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-21a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-21f).
(g)
Install PDP cover (para 3-13b).
(h)
If 11K SRW still does not pay out, notify Unit Maintenance.
3-60
Change 1