TM 9-2320-365-34-2(23) Remove thrust pump washer (24) from converter pump(3).c. Cleaning/InspectionWARNINGDry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathevapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint forType I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to complymay result in serious injury or death to personnel.If personnel become dizzy while using cleaning solvent, immediately get fresh air and medicalhelp. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaningsolvent contacts eyes, immediately flush eyes with water and get immediate medical attention.Failure to comply may result in injury to personnel.(1) Clean all metal parts with dry cleaning solvent.NOTEReplace any part that fails visual inspection orsize measurement requirements.(2) Inspect bushing (1) for scoring, pitting, or corrosion.(3) Measure inside diameter of cover bushing (1), maximuminside diameter 2.42 in. (61.47 mm).(4) Inspect converter cover (2) for cracks or damaged threads.7-7